Top rated HMI wholesale manufacturer: Order principle: That is, in accordance with the order of processing events, access to view the order (such as from the whole to a single item, from large to small, from the top to the bottom, etc.) and control processes, such as the design of monitoring management and human-machine dialogue interface and its secondary interface. Functional principle: That is, according to the specific functional requirements of the object application environment and occasions, various subsystem control types, parallel processing requirements of the same interface of different management objects and simultaneous requirements of multiple dialogues, etc., the human-computer interaction interface is designed with multi-level menus, hierarchical prompt messages and multiple dialogues, so that users can easily distinguish and master the usage rules and characteristics of the interactive interface and improve its user friendliness and ease of operation. Find more information at hmi wholesale.
System Reliability Requirements: The reliability of the general system PLC can be met. For systems with high reliability requirements, consider whether to use redundant systems or hot standby systems. PLC should be unified possible. Mainly consider the following three aspects: The model is unified, and its modules can be used as backup for each other, which is convenient for the procurement and management of spare parts. The model is unified and its function and use method are similar, which is conducive to the training of technical forces and the improvement of technical level. The model is unified, its external equipment is universal, resources can be shared, easy to network communication, and it is easy to form a multi-level distributed control system after being equipped with a computer.
Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects.
Selecting HMI screen hardware parameters, mainly look at the CPU running speed and the capacity of the memory. According to the project involves the amount of data exchange animation, the size of the pictures to choose the CPU and memory. When processing more data and picture format is large, needing to choose a fast running speed, memory slightly large HMI. For example, Mochuan 15.6Inch MC-H156E, 7Inch MC-H070CWE, MC-H070CW with 1GHz CortexTM-A7 in CPU. And 10.1Inch MC-H100C, MC-H100CWE with 1GHz cortexTM-A7 and 4GB Flash memory. In addition, also needing to consider the functional requirements needed in the project, such as, how to achieve the multi-level tital pop-up, whether the screen display meets the customer’s need…etc.
It is good to choose a brand according to the needing of the customers or the market. But it is not for selecting a brand to decide, or more about to focus on its performance parameters, and to be used the functions achieved. Actually there is an attractive story behind the famous brand. So to choose a brand, try to achieve high practicality, to avoide waste one’s talent on a petty job. For example, Siemens, Mitsubishi, Proface, Panasonic brand…etc with a good performance, but before decision to select them, should consider, how many performance of HMI panel will be used for the project? Whether the cost paid matches the performance used on the project? Read more details at https://www.mochuan-drives.com/.
Specific methods : First, the parameters of the touch screen. Check the parameter settings of the touch screen. Connect the PLC programming software to the PLC test to see what the PLC parameters are and whether the parameters set in the project are the same as those tested. There are several parameters that require special attention: 1. Communication port settings – be sure to confirm that the COM1 port or COM2 port of the PLC connected to the touch screen is clear;2. Device type – this is the most important. If the protocol is not selected correctly, nothing else needs to be said. 3. connection method – the connection between the PLC and the HMI operator interface, confirming whether it is RS485 or RS232C. 4. The touch panel interface parameter is the same as the PLC station number – it must be the same as the setting in the PLC. Next, if the parameters are set to confirm, troubleshoot the wiring.
Mochuan hmi suppliers offer free software, NO MOQ, fast shipment, to deal with us your payment and business are in safe. Offering one-to-one technical support online. The most important, our hmi wholesale is compatible with all brands of plc controllers, such as, Mitsubish FX2N, FX3U, FX3SA, FX5U…Siemens S7-200, S7-300, S7-400,…etc, ABB, Acrel, Allen-Bradley(AB), Delta, Fatek, Fuji, LS, Omron, Panasonic etc. To learn, please have a look our software, there is one list to show it.
The plastic enconomic resistive HMI panel is very high advantage competitive series. There are multiple parameter, resolution, serial port to select for user to achieve real matching per project budget for one size. But it does not mean, this type HMI touch panel performance, resolution…etc is not in perfect but more flexible. For example, there are 800×480, 1024×600 resolution, ethernet, 2xRS485, 2xRS232, RS422 are in optional for 7inch touchscreen HMI.
Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: Installation of embedded industrial hmi touch screen panel in the electrical room cabinet is more conducive to intelligent monitoring and management of the equipment in the electrical room. Through the touch screen monitoring display, you can monitor and detect the running temperature, power output, output power and other conditions of the electrical chassis cabinet in real time to ensure the stable and efficient operation of the electrical room.
Human-machine interfaces exist in all areas where human-machine information exchange is involved. A large number of industrial and commercial use, a simple distinction between “input” (Input) and “output” (Output) two, input refers to the operation of machinery or equipment by people, such as handles, switches, doors, instructions (orders) issued or maintenance, and output refers to the machinery or equipment issued by the notice, such as failure, warning, operating instructions tips, etc., a good human-machine interface will Help users more simple, more correct, more rapid operation of machinery, but also to maximize the performance of machinery and extend the service life, and the market refers to the human-machine interface is more narrowly defined in the software user-friendly operating interface.