Critical Info Blog

Don't miss any important event

Business

Transformer coil producing company today

Premium cut to length production line manufacturer: Adjustment under heavy load or short circuit conditions is not allowed: Under heavy load or short circuit conditions on the transformer, tap changer adjustment may cause arcing or excessive current, resulting in damage to the tap changer or transformer. Obey the operating procedures and safety measures: When operating the on-load pressure regulating device, you need to abide by the operating procedures and safety measures, such as wearing protective equipment and following the operating procedures to ensure safe operation. In summary, it is not allowed to operate under live conditions, frequent adjustments, heavy loads or adjustments under short-circuit conditions. When operating the on-load pressure regulating device, the operating procedures and safety measures should be followed to ensure safe and stable operation. See even more info at cut to length production line.

Adopt energy-saving measures: During the operation of the transformer, energy-saving measures can be adopted, such as adopting a high-efficiency cooling system, reducing the load rate of the transformer, optimizing the operation scheduling of the transformer, etc., to reduce energy loss and improve efficiency. Regular maintenance and overhaul: Regular maintenance and overhaul of transformers can maintain the normal operation and stability of transformers, thereby reducing energy loss and improving performance. Choose the appropriate transformer connection method: Different connection methods of the transformer will also affect the performance of the transformer. When choosing a transformer connection method, the optimal connection method can be selected according to actual needs and load characteristics to improve efficiency. To sum up, improving transformer efficiency can be achieved by optimizing design, selecting high-quality materials, adopting energy-saving measures, regular maintenance and overhaul, and selecting appropriate connection methods. In practical applications, various factors need to be considered comprehensively to select the most suitable method for improving performance.

The metal laser cutting machine focuses the laser emitted from the laser into a laser beam with high power density through the optical path system. The laser beam irradiates the surface of the workpiece to make the workpiece reach the melting point or boiling point. At the same time, the high-pressure gas coaxial with the beam blows away the molten or gasified metal. With the movement of the relative position between the beam and the workpiece, the material will finally form a slit, so as to achieve the purpose of cutting. Laser cutting process uses invisible light beam to replace the traditional mechanical knife. It has the characteristics of high precision, fast cutting, not limited to the limitation of cutting pattern, automatic typesetting, material saving, smooth incision and low processing cost. It will gradually improve or replace the traditional metal cutting process equipment.Want to konw more about metal cutting machine, contact us, one of the most professional metal laser cutting machine manufacturers & suppliers in China.

Canwin electrical equipment manufacturer provides diversified choices for customers. Distribution cabinet, power transformer equipment are available in a wide range of types and styles, in good quality and in reasonable price.Canwin collects scientific and rigorous of manufacturing and quality control management experience, in order to meet the different countries in different fields of capacitor products provide efficient, high-quality, fast service, so that the “Canwin”brand products win a good reputation all over the world.

The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.

The trademark “CANWIN” has won the title of the famous trademark of the international electrotechnical association and the trademark CANWIN CNC” has been recognized as a high -end manufacturing brand in China. We has been judged as Guangdong province enterprise that strictly contracts and keeps promises” and won the honor of”excellent supplier of Chinese electrical equipment” successively. The company has a number of national patents, and won the Guangdong provincial department of science and technology major project award the first set of domestic new products award; The company is a key enterprise in the field of electric power electrical equipment manufacturing in China, and a core professional equipment supplier of state grid, China southern power grid and many listed companies in the electric power industry. Its products are exported to countries and regions in Asia, Africa, Latin America, Europe and the United States.

As one of the best electrical equipment manufacturers & suppliers in China,Canwin specialized in transformer electrical equipment, our electrical equipment including cut to length lines, slitting lines and foil winding machines manufacturing.Electrical equipment mainly used as the iron core of various motors, generators and transformer equipment.Electrical equipment manufacturers and suppliers are currently focusing on sustainability, as global power grids must be updated to accept new forms of renewable energy, as well as IoT and enhanced communications platforms. Regardless of the specific application, electrical equipment is paired with detailed instructions for installation & maintenance and is supported by customer support services to ensure that the machine works as intended.

The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. See additional info at https://www.canwindg.com/

With the development of the times, people’s demand for power supply and the reliability of power supply are increasingly high, so the smart grid has emerged accordingly.In the power system, the core and hub of the substation is the transformer.The function of the transformer is mainly to distribute and convert electric energy. The normal operation of the transformer directly affects the normal function of the substation.The intelligent operation of the transformer mainly involves the protection and status monitoring of the transformer, so as to achieve real-time monitoring of the transformer and ultimately ensure the safety and reliability of power supply.

Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.

Harmonics, a crucial aspect of power quality, have a significant long-term impact on distribution transformers. Harmonics refer to the distortion of the normal electric current waveform, usually due to the operation of non-linear loads like computers, LED lights, and variable speed drives. These distortions can cause increased heating in the transformer, leading to accelerated aging and reduced equipment lifespan. Furthermore, harmonics can also increase power demand and system losses. They can overload the transformer and other components of the electrical system, leading to premature failures and necessitating costly repairs or replacements. Thus, managing harmonics is an essential part of maintaining high power quality and ensuring the efficient operation of power distribution transformers.