Critical Info Blog

Don't miss any important event

Pharmacy

Turn-key project for clean room factory today

Turn-key project for clean room manufacturer and supplier 2024: It can be assembled and disassembled conveniently and quickly, realizes the general standardization of temporary buildings, and establishes the concept of environmental protection, energy saving, fast and efficient construction. The temporary housing has entered a field of stereotyped products that can be serialized development, integrated production, supporting supply, and inventory. It is used in construction sites for temporary offices, dormitories, railways, transportation, water conservancy, oil, natural gas and other large-scale field exploration and field operations construction houses; urban municipal temporary commercial or other houses; leisure villas and holiday houses in tourist areas. Find more information on pharma turnkey projects.

Premium pharma clean room wholesale factory: Obstacles such as work desks in the clean room will have eddy currents at the junctions, and the cleanliness will be relatively poor near them. Drilling air return holes on the work desks will minimize eddy currents; assembly Whether the selection of materials is appropriate and whether the equipment layout is perfect are also important factors for whether the airflow becomes a vortex phenomenon. The above introduction is related to clean room and airflow influencing factors.

A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, Static control is within a certain demand range, and a specially designed room is given. That is to say, no matter how the external air conditions change, the interior can maintain the characteristics of cleanliness, temperature, humidity and pressure that were originally set. The main function of the clean room is to control the cleanliness and temperature and humidity of the atmosphere that the product comes into contact with, so that the product can be produced and manufactured in a good environmental space. We call such a space a clean room.

With our vast experience in handing national and international Pharma/Laboratory Projects.we ensure that professional integration of project will have plenty of benefits. The company has complete infrastructure and a team of experienced personnel to managing these fields more professionally. When it comes to your cleanroom certification,we have the qualifications and experience to deliver a comprehensive validation service off facilities to he requirements of all the current standard and guidelines globally.And our cleanroom are CE Market to show they meet the requirements of local country directives. Find more details at sz-pharma.com.

The connection between the wall and the floor and the ceiling should be in a concave arc shape, without gaps, leaving no dead corners. The aseptic operation room should have a unidirectional air device for air sterilization filtration, a super-clean workbench with a cleanliness of 100 or the same level, indoor temperature control of 18-26 ℃, and relative humidity of 45%-65%. The buffer room and the operating room should be equipped with UV lamps or other appropriate disinfection devices that can achieve the effect of air disinfection. The static pressure difference between adjacent rooms with different air cleanliness levels should be greater than 5Pa, and the static pressure difference between the clean room (area) and the outdoor atmosphere should be greater than 10Pa. The lighting in the aseptic room should be embedded in the ceiling, the indoor light should be evenly distributed, and the illuminance is not less than 300lx.

Pharmaceutical equipment includes: granulating oven, boiling dryer, wet machine, pulverizer, vibrating screen, slicer, drug frying machine, drug frying machine, tablet press, pill making machine, multi-functional extraction tank, liquid storage tank, liquid distribution tank, decompression drying oven, tilting reaction pot, capsule filling machine, bubble type packaging machine, particle packaging machine, powder packaging machine, V-type mixer, lifting feeder, etc.

As industries and research labs continue to embrace clean rooms as essential components of their operations, it’s crucial for professionals to understand the ideal cleanroom humidity levels within these controlled environments. Clean rooms, also known as sterile rooms or anti-static rooms, are designed to minimize contamination from dust, debris, and other environmental factors. Maintaining optimal humidity levels is an integral part of ensuring the cleanliness and functionality of clean rooms. In this blog post, we’ll discuss the normal humidity range for clean rooms and how to maintain them effectively.

The clean room workshop is also called the dust free workshop, gmp cleanroom, the industrial clean room (Clean Room) and the dust free room. It refers to the removal of pollutants such as particles, harmful air and bacteria in the air within a certain space, and the indoor temperature,cleanliness, indoor pressure, air velocity and air distribution, noise and vibration, lighting and static control. A specially designed clean room for a particular requirement. That is to say, no matter how the extemal air conditions change, the clean room can maintain the characteristics of cleanliness temperature and humidity and pressure.

For the air outlet equipped with similar diffuser, the air volume can be found out according to the air volume resistance curve of diffuser (factory air volume resistance curve or field measured air volume resistance curve) and the measured diffuser resistance (the difference between the static pressure in the orifice and the indoor pressure). When measuring, use a micro manometer and a fine pitot tube, or use a fine rubber tube to replace the pitot tube, but the plane of the measuring hole must be parallel to the air flow direction. In addition, other methods approved by the professional testing department can also be used.